summaryrefslogtreecommitdiff
path: root/firmware/target/arm/sandisk
diff options
context:
space:
mode:
Diffstat (limited to 'firmware/target/arm/sandisk')
-rw-r--r--firmware/target/arm/sandisk/powermgmt-target.h59
-rw-r--r--firmware/target/arm/sandisk/sansa-c200/powermgmt-c200.c13
-rw-r--r--firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c11
3 files changed, 60 insertions, 23 deletions
diff --git a/firmware/target/arm/sandisk/powermgmt-target.h b/firmware/target/arm/sandisk/powermgmt-target.h
new file mode 100644
index 0000000000..aa6a0e0e3d
--- /dev/null
+++ b/firmware/target/arm/sandisk/powermgmt-target.h
@@ -0,0 +1,59 @@
1/***************************************************************************
2 * __________ __ ___.
3 * Open \______ \ ____ ____ | | _\_ |__ _______ ___
4 * Source | _// _ \_/ ___\| |/ /| __ \ / _ \ \/ /
5 * Jukebox | | ( <_> ) \___| < | \_\ ( <_> > < <
6 * Firmware |____|_ /\____/ \___ >__|_ \|___ /\____/__/\_ \
7 * \/ \/ \/ \/ \/
8 * $Id$
9 *
10 * Copyright (C) 2009 by Michael Sevakis
11 * Copyright (C) 2008 by Bertrik Sikken
12 *
13 * This program is free software; you can redistribute it and/or
14 * modify it under the terms of the GNU General Public License
15 * as published by the Free Software Foundation; either version 2
16 * of the License, or (at your option) any later version.
17 *
18 * This software is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY
19 * KIND, either express or implied.
20 *
21 ****************************************************************************/
22#ifndef POWERMGMT_TARGET_H
23#define POWERMGMT_TARGET_H
24
25#if defined(SANSA_C200)
26/* This configuration triggers a single charge cycle upon plugging and stops.
27 * The true voltage cannot be read accurately and so monitoring isn't really
28 * possible. The battery filter is still synced to have a proper reading
29 * when disconnecting. */
30#define BATT_FULL_VOLTAGE 5121 /* Won't read this high - force start */
31#define BATT_VAUTO_RECHARGE 0 /* Won't read this low - force one cycle */
32#define BATT_CHG_V CHG_V_4_20V
33#define BATT_CHG_I CHG_I_300MA
34#define CHARGER_TOTAL_TIMER (4*3600*2) /* 4 hours enough? */
35#define ADC_BATTERY ADC_BVDD
36#elif defined(SANSA_E200)
37/* PREFERRED - Check if topped-off and monitor voltage while plugged. */
38#define BATT_FULL_VOLTAGE 4160
39#define BATT_VAUTO_RECHARGE 4100
40#define BATT_CHG_V CHG_V_4_20V
41#define BATT_CHG_I CHG_I_300MA
42#define CHARGER_TOTAL_TIMER (4*3600*2) /* 4 hours enough? */
43/* On e200 ADC_RTCSUP seems to represent battery voltage better than
44 * ADC_BVDD during charging (ADC_BVDD is way too high) and appears the
45 * same in normal use.
46 */
47#define ADC_BATTERY ADC_RTCSUP
48#endif
49
50void powermgmt_init_target(void);
51void charging_algorithm_step(void);
52void charging_algorithm_close(void);
53
54/* We want to be able to reset the averaging filter */
55#define HAVE_RESET_BATTERY_FILTER
56
57#define BATT_AVE_SAMPLES 32
58
59#endif /* POWERMGMT_TARGET_H */
diff --git a/firmware/target/arm/sandisk/sansa-c200/powermgmt-c200.c b/firmware/target/arm/sandisk/sansa-c200/powermgmt-c200.c
index 963e7218de..9d7a0e2965 100644
--- a/firmware/target/arm/sandisk/sansa-c200/powermgmt-c200.c
+++ b/firmware/target/arm/sandisk/sansa-c200/powermgmt-c200.c
@@ -38,8 +38,8 @@ const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
38const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] = 38const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
39{ 39{
40 40
41 /* NOTE: why is the top voltage 4237? That's just too high. */
41 { 3286, 3679, 3734, 3764, 3788, 3824, 3886, 3950, 4014, 4098, 4237 }, 42 { 3286, 3679, 3734, 3764, 3788, 3824, 3886, 3950, 4014, 4098, 4237 },
42
43}; 43};
44 44
45/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */ 45/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
@@ -48,14 +48,3 @@ const unsigned short percent_to_volt_charge[11] =
48 /* Sansa c200 has a 530 mAh LiPo battery */ 48 /* Sansa c200 has a 530 mAh LiPo battery */
49 3300, 3390, 3480, 3570, 3660, 3750, 3840, 3930, 4020, 4110, 4200 49 3300, 3390, 3480, 3570, 3660, 3750, 3840, 3930, 4020, 4110, 4200
50}; 50};
51
52/* ADC should read 0x3ff=5.12V */
53#define BATTERY_SCALE_FACTOR 5125
54/* full-scale ADC readout (2^10) in millivolt */
55
56/* Returns battery voltage from ADC [millivolts] */
57unsigned int battery_adc_voltage(void)
58{
59 return (adc_read(ADC_UNREG_POWER) * BATTERY_SCALE_FACTOR) >> 10;
60}
61
diff --git a/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c b/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c
index 43f37463f8..144ca37ebf 100644
--- a/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c
+++ b/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c
@@ -47,14 +47,3 @@ const unsigned short percent_to_volt_charge[11] =
47 /* Sansa Li Ion 750mAH FIXME */ 47 /* Sansa Li Ion 750mAH FIXME */
48 3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160 48 3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160
49}; 49};
50
51/* ADC should read 0x3ff=5.12V */
52#define BATTERY_SCALE_FACTOR 5125
53/* full-scale ADC readout (2^10) in millivolt */
54
55/* Returns battery voltage from ADC [millivolts] */
56unsigned int battery_adc_voltage(void)
57{
58 return (adc_read(ADC_UNREG_POWER) * BATTERY_SCALE_FACTOR) >> 10;
59}
60