From 2ca5774cf9613b0f2c1d31d6054911b8cb36e131 Mon Sep 17 00:00:00 2001 From: Tomasz Moń Date: Sun, 20 Jun 2021 10:06:32 +0200 Subject: Sansa Connect: Indicate charging status Consider battery level down to 0 as safe as OF continues to operate normally even when at level 0. Change-Id: Ie3889e5662b9fa6588e20ad02d8953f29e28800c --- .../arm/tms320dm320/sansa-connect/power-sansaconnect.c | 14 -------------- 1 file changed, 14 deletions(-) (limited to 'firmware/target/arm/tms320dm320/sansa-connect/power-sansaconnect.c') diff --git a/firmware/target/arm/tms320dm320/sansa-connect/power-sansaconnect.c b/firmware/target/arm/tms320dm320/sansa-connect/power-sansaconnect.c index ecdf3b1a75..b139572605 100644 --- a/firmware/target/arm/tms320dm320/sansa-connect/power-sansaconnect.c +++ b/firmware/target/arm/tms320dm320/sansa-connect/power-sansaconnect.c @@ -74,21 +74,7 @@ void power_off(void) avr_hid_power_off(); } -#if CONFIG_CHARGING -unsigned int power_input_status(void) -{ - return POWER_INPUT_NONE; -} - -/* Returns true if the unit is charging the batteries. */ -bool charging_state(void) -{ - return false; -} -#endif - void ide_power_enable(bool on) { (void)on; } - -- cgit v1.2.3