From 0fac492c3da8b46ad1cf5a668e5d851c63443a94 Mon Sep 17 00:00:00 2001 From: Jens Arnold Date: Fri, 17 Aug 2007 06:45:18 +0000 Subject: First step of powermanagement rework: * Move target specific stuff into target tree, starting with battery voltage tables and voltage reading. (This revealed some incorrect percent_to_voltage_charging mappings). * Voltage reading on 1st gen ipods is now correct. * Clean up obsolete config #defines. git-svn-id: svn://svn.rockbox.org/rockbox/trunk@14375 a1c6a512-1295-4272-9138-f99709370657 --- firmware/export/config-h10_5gb.h | 3 --- 1 file changed, 3 deletions(-) (limited to 'firmware/export/config-h10_5gb.h') diff --git a/firmware/export/config-h10_5gb.h b/firmware/export/config-h10_5gb.h index 254f59fa35..d45b6e3064 100644 --- a/firmware/export/config-h10_5gb.h +++ b/firmware/export/config-h10_5gb.h @@ -79,14 +79,11 @@ #define AB_REPEAT_ENABLE 1 -/* Type of mobile power */ -#define CONFIG_BATTERY BATT_BP009 #define BATTERY_CAPACITY_DEFAULT 820 /* default battery capacity */ #define BATTERY_CAPACITY_MIN 700 /* min. capacity selectable */ #define BATTERY_CAPACITY_MAX 900 /* max. capacity selectable */ #define BATTERY_CAPACITY_INC 10 /* capacity increment */ #define BATTERY_TYPES_COUNT 1 /* only one type */ -#define BATTERY_SCALE_FACTOR 4688 /* Hardware controlled charging */ #define CONFIG_CHARGING CHARGING_SIMPLE -- cgit v1.2.3