From 5ead6a60568d268e112b6753dde8d3e40808ac07 Mon Sep 17 00:00:00 2001 From: Andree Buschmann Date: Fri, 11 Feb 2011 15:58:39 +0000 Subject: Submit FS#11926, calibrate charge curve for e200v1. Thanks to Martin Ritter. git-svn-id: svn://svn.rockbox.org/rockbox/trunk@29282 a1c6a512-1295-4272-9138-f99709370657 --- firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c | 4 ++-- 1 file changed, 2 insertions(+), 2 deletions(-) diff --git a/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c b/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c index d4ab31eab9..6b7a47b74d 100644 --- a/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c +++ b/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c @@ -43,6 +43,6 @@ const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] = /* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */ const unsigned short percent_to_volt_charge[11] = { - /* Sansa Li Ion 750mAH FIXME */ - 3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160 + /* Sansa Li Ion 750mAH */ + 3700, 3900, 3950, 3985, 4030, 4095, 4150, 4173, 4185, 4195, 4200 }; -- cgit v1.2.3