summaryrefslogtreecommitdiff
diff options
context:
space:
mode:
-rw-r--r--firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c8
1 files changed, 4 insertions, 4 deletions
diff --git a/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c b/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c
index 388ebaed43..9bb70263be 100644
--- a/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c
+++ b/firmware/target/arm/sandisk/sansa-e200/powermgmt-e200.c
@@ -35,15 +35,15 @@ const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
35/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */ 35/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
36const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] = 36const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
37{ 37{
38 /* Sansa Li Ion 750mAH FIXME this is a first linear approach */ 38 /* Sansa Li Ion 750mAH, took from battery benchs */
39 { 3300, 3390, 3480, 3570, 3660, 3750, 3840, 3930, 4020, 4110, 4200 }, 39 { 3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160 },
40}; 40};
41 41
42/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */ 42/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
43const unsigned short percent_to_volt_charge[11] = 43const unsigned short percent_to_volt_charge[11] =
44{ 44{
45 /* Sansa Li Ion 750mAH FIXME*/ 45 /* Sansa Li Ion 750mAH FIXME */
46 3300, 3390, 3480, 3570, 3660, 3750, 3840, 3930, 4020, 4110, 4200 46 3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160
47}; 47};
48 48
49/* ADC should read 0x3ff=5.12V */ 49/* ADC should read 0x3ff=5.12V */